page 1 of 3 hbd dc/dc series data sheet rev. sep 05, 2003 60-watt, dual output hbd060yge-a 60 65 70 75 80 85 10 20 30 40 50 60 70 80 90 100 load % efficiency % eff. (18v) eff. (24v) eff. (36v) 50 55 60 65 70 75 80 85 10 20 30 40 50 60 70 80 90 100 load % efficiency % hbd060zge-a hbd040zge-a hbd040zed-a technical specifications voltage range 24 vdc nominal 18.00 - 36.00 vdc 48 vdc nominal 34.00 - 75.00 vdc reflected ripple 80 ma input reverse voltage protection shunt diode hbd dual output, dc/dc converters feature high efficiency, 1500 vdc isolation, and open-frame packaging. the hbd family allows board designers to deliver any combination of power from either output, up to each model?s maximum rating. the hbd is available in 5v/3.3v or 3.3v/2.5v combinations in either a 24v or 48v input version. the hbd uses planar magnetics and has an mtbf of over a million hours. ? independent dual outputs ? flexible load sharing ? high efficiency topology ? open-frame design ? planar magnetics ? independent trim for each output ? 1500v isolation ? 100c baseplate operation description features input efficiency vs. load (24v input) efficiency vs. load (48v input) notes 1 for negative logic, add suffix ?n? to model number. ? mtbf predictions may vary slightly from model to model. specifications typically at 25c, normal line, and full load, unless otherwise stated. soldering conditions: i/o pins, 260c, ten seconds; fully compatible with commercial wave-soldering equipment. safety: agency approvals may vary from model to model. please consult factory for specific model information. units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. turn-on time 10 ms remote shutdown positive logic switching frequency 500 khz isolation input - output 1500 vdc input - case 1050 vdc output - case 500 vdc temperature coefficient 0.03%/c case temperature operating range -40 to +100c storage range -40 to +125c thermal shutdown range 105 to 115c humidity max., non-condensing 95% vibration, 3 axes, 5 min each 5 g mtbf ? (bellcore tr-nwt-000332) 1.3 x 10 6 hrs safety ul, cul, vde weight (approx.) 2.4 oz general setpoint accuracy 1% line regulation v in min. - v in max., i out rated, output 1 0.2% v out line regulation v in min. - v in max., i out rated, output 2 1.0% v out load regulation i out min. - i out max., v in nom., output 1 0.5% v out load regulation i out min. - i out max., v in nom., output2 1.0% v out minimum output current 10% i out rated dynamic regulation, loadstep 25% i out pk deviation 4% v out settling time 500 m s voltage trim range (5v/3.3v units) 10% power limit threshold range, % of i out rated 110 - 140% ovp trip range (main ouput) 115 - 140% v out nom. output
page 2 of 3 model input voltage input voltage maximum input output rated output ripple & noise typical (volts) range (volts) current (amps)* voltage (volts) current (amps) pk-pk (mv) efficiency** hbd040yed-a 24 18-36 2.89 3.3/2.5 12/15 75/75 75% hbd060yge-a 24 18-36 4.54 5.0/3.3 12/15 100/75 78% hbd040yge-a 24 18-36 3.02 5.0/3.3 8/12 100/75 80% hbd040zge-a 48 34-75 1.51 5.0/3.3 8/12 100/75 80% hbd040zed-a 48 34-75 1.62 3.3/2.5 12/15 75/75 75% hbd060zge-a 48 34-75 2.27 5.0/3.3 12/15 75/75 75% notes: * maximum input current at minimum input voltage, maximum rated output power. ** at nominal v in , rated output. note: current can be drawn from either output to its maximum value, or from both outputs to a combined total of 15a. hbd dc/dc series data sheet rev. sep 05, 2003 60-watt, dual output thermal impedance natural convection 6.6 c/w 100 lfm 5.7 c/w 200 lfm 4.2 c/w 300 lfm 3.1 c/w 400 lfm 2.6 c/w tolerances note: thermal impedance data is dependent on many environmental factors. the exact thermal performance should be validated for specific application. mechanical drawing 1-v in 2 case 3 on/off 4+v in 5+v out 2 6- v out 2 7 trim 2 8+v out 1 9-v out 1 10 trim 1 inches: (millimeters) .xx 0.020 .x 0.5 .xxx 0.010 .xx 0.25 pin: 0.002 0.05 (dimensions as listed unless otherwise specified.) pin function
! "# $
$! $%
% model selection
page 3 of 3 rev. sep 05, 2003 options option suffix applicable series remarks negative logic n has, hbd, hbs, hes, hls, hld, les, ttl "low" turns module on qbs, qes, qls, tes, tqd ttl "high" turns module off lucent-compatible trim t has, hbd, hbs, hes, hls, qbs, qes, qls trim 1 ias, les enable 2 iad, ias, les, sms trim and enable 3 ias, les pin length and heatsink options standard pin length is 0.180" (4.6mm) 0.110" (2.8mm) pin length 8 all leaded models 0.150" (3.8mm) pin length 9 all leaded models 0.24" (6.1mm) horizontal heatsink 1h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.24" (6.1mm) vertical heatsink 1v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) horizontal heatsink 2h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.45" (11.4mm) vertical heatsink 2v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) horizontal heatsink 3h all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) 0.95" (24.1mm) vertical heatsink 3v all 1/4-bricks, 1/2-bricks, 3/4-bricks, full-bricks includes thermal pad (except hls, hld, qls, tld, and tkd packages) this page is offered as a reference. consult factory for actual availability of options. when ordering equip- ment options, use the following suffix information. select preferred option(s) and add the suffix to the model number. ordering option examples are located below the options table. example options: hbs050zg-ant3v = hbs050zg-a with negative logic, lucent-compatible trim, and 0.95? vertical heatsink. les015yj-3n = les015yj with optional trim and enable, negative logic. qbs066zg-at8 = qbs066zg-a with lucent-compatible trim and 0.110? pin length. nuclear and medical applications - power-one products are not authorized for use as critical components in life support systems, equip- ment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisiona l president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice.
|